High Voltage model VLF-4022CM AC Hipot Tester

No stress rentals! We help you to choose the equipment that you need, we expedite shipment, and follow up.

High Voltage model VLF-4022CM AC Hipot Tester
  • Features & specifications

  • Input (CM suffix): 120V, 60Hz, 5 amps peak, 2.5 amps average
  • Input (F suffix): 230V, 50/60Hz, 3 amps peak, 2 amps average
  • Output: 0 to 40kVac peak, frequency selectable at 0.1/0.05/0.02 Hz
  • Duty continuous and rated load: 1.1 μF at 0.1 Hz, 2.2 μF at 0.05 Hz, 5.5 μF at 0.02 Hz
  • Comprises a control unit (50 lb) and a high voltage tank (72 lb)
  • Voltmeter: -40 kVac to +40 kVac peak
  • Charging Current meter: 0 to 100mA peak
  • Load Capacitance meter: 0 to 6 Microfarads peak
  • Shielded RG/BU output cable: 20 ft. (6 m), Interconnect cable: 10 ft. (3 m)
  • Shipping weight: Approximately 175 lbs.

Specifications
Input 120 volts, 60 Hz, 10 A peak, 5 A average
or 230 volts, 50/60 Hz, 6 A peak
Output 0 - 44 kVac peak, 0.1/0.05/0.02 Hz sinusoidal
Duty Continuous
Load rating 1.1 μF @ 0.1 Hz, 2.2μF @ 0.05 Hz, & 5.5 μF @ 0.02 Hz
Metering Voltmeter: Center Zero -45 to 0 to +45 kVac peak
Charging Current meter: 0 to 100 mA peak
Load capacitance meter: 0 - 6 Microfarads
Cable lengths Shielded EPR output cable: 20 ft. (6 m)
Interconnect cable: 10 ft. (3 m)
Size & Weight Controls: 22"W x 11.25"D x 15.25"H, 50 lbs.
559 mm W x 286 mm D x 387 mm H, 23 kg
HV Tank: 14.5"W x 10.5"D x 19"H, 72 lbs.
368 mm W x 267 mm D x 483 mm H, 33 kg