No stress rentals! We help you to choose the equipment that you need, we expedite shipment, and follow up.
Technical characteristics | |
---|---|
Bandwidth | DC to 8 GHz |
Maximum capture BW | 36 MHz |
Memory | 64 MB / 256 MB |
DANL, 1 GHz | -151 dBm/Hz |
Interface ports | GPIB, LAN, USB(2) |
Frequency response | 100 kHz to 40 MHz: ± 0.5 dB, ± 0.3 dB (typical) 40 MHz to 3 GHz: ± 1.2 dB, ± 0.5 dB (typical) 3 GHz to 6.5 GHz: ± 1.7 dB, ± 1.0 dB (typical) 5 GHz to 8 GHz: ± 1.7 dB, ± 1.0 dB (typical) |
Center Frequency Setting Resolution | 0.1 Hz |
RBW Filter Bandwidth Accuracy | 0.1% |
External Reference Input | 10 MHz, -10 dBm to + 6 dBm |
Resolution Bandwidth | Range: 1 Hz to 10 MHz, automatically selected or user-defined Accuracy: Within 6.0% ± 0.1% |
Noise Bandwidth Range (RTSA Mode) |
313.18 MHz to 400.87 kHz |
Displayed Average Noise Level (Specified) |
10 MHz: -151 dBm/Hz 2 GHz: -150 dBM/Hz 3 GHz: -150 dBm/Hz 7 GHz: -142 dBm/Hz |
Displayed Average Noise Level (Typical) |
1 kHz to 10 kHz: –144 dBm/Hz 10 kHz to 10 MHz: -151 dBm/Hz 10 MHz to 100 MHz: -151 dBm/Hz 100 MHz to 1 GHz: -150 dBm/Hz 1 GHz to 2 GHz: -150 dBm/Hz 2 GHz to 3 GHz: -150 dBm/Hz 3 GHz to 5 GHz: -142 dBm/Hz 5 GHz to 8 GHz: -142 dBm/Hz |
Options | |
Option 02 | 65.5 MSample Deep Memory, Frequency Mask Trigger |
Option 3 | IQ, Differential IQ Inputs |
Option 05 | Digital IQ Output |
Option 06 | 40 GB removable HDD |
Option 10 | Audio Distortion Analysis |
Option 21 | Advanced Measurement Suite Software (GP Mod. Analysis, RFID, Sig. Source) |
Option 24 | GSM/EDGE Analysis |
Option 25 | CDMA 1X Forward/Reverse Link Analysis |
Option 26 | 1X EVDO Forward/Reverse Link Analysis |
Option 28 | TD-SCDMA Analysis |
Option 29 | WLAN 802.11a/b/g/n Analysis |
Option 30 | 3GPP Release 99 (W-CDMA) and Release 5 UL/DL(HSDPA) Analysis |
Option 40 | 3GPP Release 6 (HSUPA UL/DL) Analysis(requires Opt. 30) |
General characteristics | |
Operating temperature | +10 °C to +40 °C |
Storage temperature | -20 °C to +60 °C |
Warm up time | 20 min. |
Operating altitude | Up to 3,000 m (approximately 10,000 ft.) |
Non-operating altitude | Up to 12,190 m (40,000 ft.) |
Power requirements | 100 V AC to 240 V AC, 47 Hz to 63 Hz |
Power consumption | 400 VA max |
Safety & EMI compatibility | UL 61010-1; CSA C22.2 No. 61010-1-xx IEC61010, second edition (Self Declaration) Low Voltage Directive 2006/95/EC; EN61010-1: 2001Safety requirements for Electrical Equipment forMeasurement, Control, and Laboratory Use EC Council EMC Directive2004/108/EEC;EN61326:1997 Product FamilyStandard for Electrical Equipment for Measurement,Control, and Laboratory Use – EMC Requirements Radio communications Act:1992, EMC RegulatoryArrangements, AS/NZS CISPR 11 (Industrial,Scientific, and Medical Equipment) |
Calibration interval | 1 year |
Dimensions | Height: 215 mm Depth: 425 mm Width: 425 mm |
Weight | 20 kg, 44 lb |