Tektronix RSA3303A Spectrum Analyzer
  • Application

  • System integration of RF Systems, RFID system development & troubleshooting, general purpose Phase Noise and Jitter signal analysis, troubleshooting RF components, modules or systems, and much more.
  • Features & specifications

  • Frequency range: DC to 3 GHz
  • Real-time capture bandwidth: 15 MHz
  • Resolution bandwidth: 1 Hz to 10 MHz, auto or user defined
  • Memory depth: 16.384 Msamples (65.536 Msamples with option 2)
  • Dynamic range: DC to 20 MHz

Specifications
Technical characteristics
Bandwidth DC to 3 GHz
Frequency response 100 kHz to 40 MHz: ± 0.5 dB, ± 0.3 dB (typical)
40 MHz to 3 GHz: ± 1.2 dB, ± 0.5 dB (typical)
Center Frequency Setting Resolution 0.1 Hz
RBW Filter Bandwidth Accuracy 0.1%
External Reference Input 10 MHz, -10 dBm to + 6 dBm
Resolution Bandwidth Range: 1 Hz to 10 MHz, automatically selected or user-defined
Accuracy: Within 6.0% ± 0.1%
Noise Bandwidth Range
(RTSA Mode)
313.18 MHz to 400.87 kHz
Displayed Average Noise Level
(Specified)
10 MHz: -151 dBm/Hz
2 GHz: -150 dBM/Hz
3 GHz: -150 dBm/Hz
Displayed Average Noise Level
(Typical)
1 kHz to 10 kHz: –144 dBm/Hz
10 kHz to 10 MHz: -151 dBm/Hz
10 MHz to 100 MHz: -151 dBm/Hz
100 MHz to 1 GHz: -150 dBm/Hz
1 GHz to 2 GHz: -150 dBm/Hz
2 GHz to 3 GHz: -150 dBm/Hz
Options
Option 02 65.5 MSample Deep Memory, Frequency Mask Trigger
Option 3 IQ, Differential IQ Inputs
Option 21 Advanced Measurement Suite Software
Option 1A External Preamp, 100 MHz to 3 GHz, 20 dB gain, 6.5 dB Noise Figure at 2 GHz (typical)
Option 1R Rackmount kit
Option SASW USB Stand-alone Software Key
General characteristics
Operating temperature +10 °C to +40 °C
Storage temperature -20 °C to +60 °C
Warm up time 20 min.
Operating altitude Up to 3,000 m (approximately 10,000 ft.)
Non-operating altitude Up to 12,000 m (40,000 ft.)
Power requirements 100 V AC to 240 V AC, 47 Hz to 63 Hz
Power consumption 400 VA max
Safety & EMI compatibility UL 61010-1; CSA C22.2 No. 61010-1-04;IEC61010, Second Edition (Self Declaration)
Low Voltage Directive 73/23/EEC, amended by93/68/EEC; EN61010-1: 2001 Safety Requirementsfor Electrical Equipment for Measurement Control and Laboratory Use
EC Council EMC Directive 89/336/EEC, amended by 93/68/EEC
EN61326-1: 1997 Product Family Standard for Electrical Equipment for Measurement, Control and Laboratory Use-EMC Requirements
Electromagnetic Compatibility Framework: 1992AS/NZS 2064.1/2 (Industrial, Scientific and MedicalEquipment)
Calibration interval 1 year
Dimensions Height: 215 mm
Depth: 425 mm
Width: 425 mm