No stress rentals! We help you to choose the equipment that you need, we expedite shipment, and follow up.
Input | PTS-75: 120Vac, 50/60Hz, 10A PTS-75F5: 230Vac, 50Hz, 5A PTS-75F5: 230Vac, 60Hz, 5A ±1% input voltage regulator1,2 |
---|---|
Output | 0 to 75 kV DC & 10 mA, negative polarity, positive ground |
Duty | Continuous capacitive charging |
Voltmeter | 3.5 in., scaled 0 to 37.5/75 kV DC, ±2% of full scale |
Current Meter | 3.5 in., scaled 0 to 1.0 μA DC, ±2% of full scale with multipliers of x 1, x 10, x 100, x 1 k, x 10k Guard/ground load return |
Megohmmeter | Scaled 100Ω to 1 MΩ with multipliers of x 0.1, x 1, x 10, x 100, x 1 k |
Size & Weight (W x D x H) |
14 x 11 x 18 in., 68 lb. 356 x 279 x 457 mm, 31 kg |
Shipping weight | 110 lb., 50 kg |
Output Termination | 20 ft. (6 m) shielded output cable with alligator clamp |
Accessories | 20 ft. (6 m) return lead with alligator clamp 20 ft. (6 m) ground lead with alligator clamp 10 ft. (3 m) input line cord Ground stick with 20 ft. (6 m) lead and clamp |
Note 1: | Due to the ferro-resonant designed input voltage regulator, if an inverter is used for the voltage source, it must produce a "true sine wave" output, not a "modified sine wave" (square wave). |
Note 2: | This model is input frequency sensitive: either 50 Hz or 60 Hz. Please specify when ordering. |