High Voltage model PTS-75 DC Hipot Tester

No stress rentals! We help you to choose the equipment that you need, we expedite shipment, and follow up.

High Voltage model PTS-75 DC Hipot Tester
  • Features & specifications

  • 75kV DC Hipot Tester
  • Control panel and tank housed in a single 68lb enclosure
  • Input is 120V, 10A, 60Hz
  • Output is 0 to 75kV DC, 10mA negative polarity, positive ground
  • Continuous duty with capacitive charging
  • Ripple is less than 2.5%, RMS resistive load, (N/A for capacitive load)

Specifications
Input PTS-75: 120Vac, 50/60Hz, 10A
PTS-75F5: 230Vac, 50Hz, 5A
PTS-75F5: 230Vac, 60Hz, 5A
±1% input voltage regulator1,2
Output 0 to 75 kV DC & 10 mA, negative polarity, positive ground
Duty Continuous capacitive charging
Voltmeter 3.5 in., scaled 0 to 37.5/75 kV DC, ±2% of full scale
Current Meter 3.5 in., scaled 0 to 1.0 μA DC, ±2% of full scale with multipliers of x 1, x 10, x 100, x 1 k, x 10k
Guard/ground load return
Megohmmeter Scaled 100Ω to 1 MΩ with multipliers of x 0.1, x 1, x 10, x 100, x 1 k
Size & Weight
(W x D x H)
14 x 11 x 18 in., 68 lb.
356 x 279 x 457 mm, 31 kg
Shipping weight 110 lb., 50 kg
Output Termination 20 ft. (6 m) shielded output cable with alligator clamp
Accessories 20 ft. (6 m) return lead with alligator clamp
20 ft. (6 m) ground lead with alligator clamp
10 ft. (3 m) input line cord
Ground stick with 20 ft. (6 m) lead and clamp
Note 1: Due to the ferro-resonant designed input voltage regulator, if an inverter is used for the voltage source, it must produce a "true sine wave" output, not a "modified sine wave" (square wave).
Note 2: This model is input frequency sensitive: either 50 Hz or 60 Hz. Please specify when ordering.