Phenix 4200-5 200 kV DC Hipot Tester

No stress rentals! We help you to choose the equipment that you need, we expedite shipment, and follow up.

Phenix 4200-5 200 kV DC Hipot Tester
  • Application

  • The accurate and rugged Phenix 4200-5 generates 200 kV DC with a maximum current output of 5 mA. The level of ripple is very low, at less than 2% RMS at full output.
  • Key features

  • Generates 200 kV DC at 5 mA
  • Ruggedly constructed with user-friendly controls
  • Very low ripple, < 2% RMS at full output
  • Guard mode for accurate current measurements
  • Manual control of output voltage

Specifications
Electrical specifications
Input power 110 to 120 V, 10 A
220 to 240 V, 5 A
Input frequency 50/60 Hz
Output voltage ˜ 0 to 200 kV, 5 mA
Duty cycle Continuous capacitive charging at 5 mA
Internal discharge device 12 kJ
Metering accuracy 3½ digit, 0.5% of full scale
Voltmeter range 0 to 0-19.99/200 kV
Current meter ranges 0 to 19.99 μA/ 199.9 μA/ 1.999 mA/ 19.99 mA
Output Charging Indicator 1.5 in. analog, 0 to 100% of selected range indication
Cables included Input power: 7 ft (2 m)
High voltage: 20 ft (6 m)
Ground: 20 ft (6 m)
Ground: 20 ft (6 m), qty 2
Return: 20 ft (6 m)
Power interconnect: 25 ft (8 m)
Physical specifications
Control section Dimensions: (L 21 x W 17 x H 14)in (533 x 432 x 355)mm
Weight: 42 lbs (19 kg)
High voltage tank Dimensions: (L 23 x W 19 x H 35)in (584 x 483 x 889)mm
Weight: 375 lbs (170 kg)
Operating temperature 10 to 40 °C, indoor/outdoor in fair weather
Humidity (operating) < 95% non-condensing
Altitude < 3300 ft (1000 meters)
For detailed specifications please see: Phenix 4200-5 Data Sheet