No stress rentals! We help you to choose the equipment that you need, we expedite shipment, and follow up.
Input | 120 V, 60 Hz, 15A, or 230 V, 50/60 Hz, 8A |
---|---|
HV Output | 0-30 kVac, 1kVA resistive load 3 kVA capacitive load Up to 100 mA current |
No Load Current | 14 mA NB: 3 kVA output power is only available with a capacitive load sized to draw 3 kVA at full rated output. Available output current decreases with other loads |
Output Termination | 20 ft. (6m) long shielded output cable with alligator clamp and hook for test connections |
Duty | 3kVA: 1 hour ON, 1 hour OFF 1kVA: continuous |
Distortion | < 5% |
Meter accuracy | 2% of full scale |
Kilovolt Meter | 3.5 inch Scaled 0-12/30 kVac |
Current Meter | 3.5 inch Scaled 0-1.0 mAac, with x1, x10, x100 Range Multiplier |
Control dimensions | 21"W x 11.25"D x 15.25"H 533 mm W x 286 mm D x 387 mm H |
HV Tank dimensions | High Voltage Tank included in controls |
Weight | 75 lbs. (34kg) |