No stress rentals! We help you to choose the equipment that you need, we expedite shipment, and follow up.
Wavelength (nm) | 850 ± 20, 1300 ± 20, 1310 ± 20, 1550 ± 20, 1625 ± 15 (filtered) |
---|---|
Dynamic range (dB) | 27, 26, 36, 34, 34 |
Event dead zone (m) | 0.8 |
Attenuation dead zone (m) | 4, 4.5, 5, 5, 5 |
Distance range (km) | Multimode: 0.1, 0.3, 0.5, 1.3, 2.5, 5, 10, 20, 40 Singlemode: 1.25, 2.5, 5, 10, 20, 40, 80, 160, 260 |
Pulse width (ns) | Multimode: 5, 10, 30, 50, 100, 275, 500, 1000 Singlemode: 5, 10, 30, 50, 100, 275, 500, 1000, 2500, 10000, 20000 |
Launch conditions | Encircled Flux (EF) compliant |
Linearity (dB/dB) | ±0.03 |
Loss threshold (dB) | 0.01 |
Loss resolution (dB) | 0.001 |
Sampling resolution (m) | Multimode: 0.04 to 2.5 Singlemode: 0.04 to 5 |
Sampling points | Up to 256 000 |
Distance uncertainty (m) | ±(0.75 + 0.0025 % x distance + sampling resolution) |
Measurement time | User-defined (60 min. maximum) |
Typical real-time refresh (Hz) | 3 |
Stable source output power (dBm) | −3 (1300 nm), −7 (1550 nm) |