AEMC 8336 Power Quality Analyzer

No stress rentals! We help you to choose the equipment that you need, we expedite shipment, and follow up.

AEMC 8336 Power Quality Analyzer
  • Features of PowerPad® III Model 8336

  • Measurement of TRMS voltages up to 1000Vrms AD/DC for two-, three-, four- or five-wire systems
  • Measurement of TRMS currents up to 10kArms (sensor dependent)
  • Measures up to 5000ADC with the AC/DC Current Probe Model J93
  • Frequency measurement (40 to 70Hz systems)
  • Captures up to 210 transient occurrences on all V and A inputs
  • Available for rent or purchase (new)

Electrical specifications
Input Terminals 5 voltage / 4 current
Inputs 4 voltage / 4 current
Voltage (TRMS AC+DC) 2 to 1000V
Voltage Ratio up to 500kV
Current (TRMS AC+DC) MN93: 500mA to 200AAC
MN193: 0.005 to 100AAC
SR193 Clamp: 1A to 1000AAC
AmpFlex® or MA193 Clamps: 100mA to 10000AAC
MR193 Clamp: 1A to 1300AAC/DC
SL261 Clamp: 50mA to 100AAC/DC
J93: 50 to 3500AAC/DC
Current Ratio: up to 60kV
Frequency (Hz) 40 to 69Hz
Distribution Systems 1P 2W, 1P 3W, 2P 2W, 2P 3W, 2P 4W, 3P 3W, 3P 4W and 3p 5W, 2½ Element & Aron meters
Power Values W, VA, var, VAD, PF, DPF, cosΦ, tanΦ
Energy Values Wh, varh, VAh, VADh
Harmonics 1st to 50th, Direction, Sequence; THD: 0 to 50, phase
Transients up to 210
Flicker (Pst & Plt) Yes
Inrush Mode Yes, >10 min
Unbalance Yes
Recording Yes
Alarm Mode 40 types; 10,000 recorded
Peak Yes
Phasor Display Automatic
Display Color ¼ VGA TFT screen (320 x 240) diagonal 148mm
Snapshots 50
Electrical Safety IEC 61010, 1000V CAT III / 600V CAT IV
Protection IP53
Languages more than 27
Communication Interface USB
Battery Life >13 hrs, 25 hrs in Record Mode
Power Supply 9.6V NiMH rechargeable battery pack (included) External AC supply: 110/230Vac ±10% (50/60Hz)

General specifications
Applications Verification of power distribution circuits
In-plant troubleshooting of power distribution panels and individual machinery
Monitor pad-mount transformers and phase unbalances
Determine harmonic problems originating from source or load
Determine transformer K-Factor
Energy metering (kVAh, VARh, kWh)
Standards IEC 61000-4-30 Class B and safety rated to 600V CAT IV
Harmonics Measures harmonics for voltage, current or power up to the 50th harmonic
Transients Records and time stamps disturbances such as swells, sags, spikes, brownouts, etc.
Power Measures energy VAh, VARh & Wh
Recording speed 65μs/sample transient recording
Software Free DataView® software is included for configuring real-time display and report generation
Data memory 2GB of memory available for storing trend data
Internal memory Additional internal memory stores alarms, transients, and snapshot data. Note: The user can store up to 50 screen snapshots, up to 210 captured transients that contain four cycles for each active input, and 10,000 alarm events from up to 40 different parameters. Trend data can also be recorded for days, weeks or even months. Inrush current can also be captured and stored.
Accessories included Qty 4: 193-24 Ampflex Current Probes
Qty 5: Black 10 ft Voltage Leads
Qty 5: Black Alligator Clips
Qty 12: Color-Coded Input ID Markers
Qty 1: USB Cable, NiMH Battery
Qty 1: 110/240V Power Adapter with US Power Cord
Qty 1: Large Classic Tool Bag
Qty 1: Soft Carrying Pouch
Qty 1: User manual (USB stick)
Qty 1: DataView software
Dimensions / Weight (9.8 x 7.8 x 2.6)in. (240 x 180 x 55)mm / 4.3 lbs (1.95kg