TES-3079K HVAC Clamp Meter
  • Feature summary

  • Check current draw in motors and compressors
  • Use MAX/MIN/Recording in the temperature mode to assess efficiency
  • Test run/start capacitors
  • Confirm low voltage control signals
  • Measure flame safeguard device current draw
  • Confirm power sources
  • Analyze temperature and power data with the aid of the time stamp
  • Price: $162.00 US dollars

Specifications: (23°C ± 5°C)
AC Current: (Trms, 50Hz to 400Hz, Overload protection 1000A)
Range Resolution Accuracy Sensitivity
99.99A 10mA ± 2.0% ± 20dgts (50, 60Hz) 0.10A
999.9A 100mA ± 4.0% ± 20dgts (40-400Hz) 1.0A

μA: (Trms AC & DC. Burden Voltage 5mV/μA)
Range Resolution Accuracy Sensitivity
99.99μA 10nA ± 1% ± 20dgts 0.20μA
999.9μA 100nA ± 1% ± 20dgts 2.0μA

AC Voltage: (Trms, 50Hz-400Hz. Overload protection 600V)
Range Resolution Accuracy Sensitivity
999.9mV 0.1mV ± 1% ± 20dgts (50, 60Hz)
± 2% ± 20dgts (40-400Hz)
2.0mV
9.999V 1mV ± 1% ± 20dgts (50, 60Hz)
± 2% ± 20dgts (40-400Hz)
0.020V
99.99V 10mV 0.20V
600.0V 100mV 2V

DC Voltage: (Overload protection 600V)
Range Resolution Accuracy Sensitivity
999.9mV 0.1mV ± 1.0% ± 20dgts 2.0mV
9.999V 1mV 20mV
99.99V 10mV 200mV
600.0V 100mV 2V

Resistance: (Continuity < 40Ω on the 999.9Ω range)
Range Resolution Accuracy Overload Protection
999.9Ω 100mΩ ± 1% ± 10dgts 600V
9.999kΩ ± 1% ± 10dgts 600V
99.99kΩ 10Ω ± 1% ± 10dgts 600V
999.9kΩ 100Ω ± 1% ± 10dgts 600V

Resistance (MΩ):
Range Resolution Accuracy Overload Protection
9.999MΩ 1kΩ ± 5% ± 10dgts 600V
99.99MΩ 10kΩ ± 5% ± 10dgts 600V

Capacitance:
Range Resolution Accuracy Overload Protection
10.000μF 1nF ± 1.5% ± 5dgts 600V
100.00μF 10nF ± 1.5% ± 5dgts 600V
1000.0μF 100nF ± 1.5% ± 5dgts 600V
7000μF 1μF ± 2.5% ± 15dgts 600V

Diode: (Continuity < 40mV)
Range Resolution Accuracy Overload Protection
2.000V 1mV ± 2% ± 1dgt 600V

Temperature: (K-Type thermocouple)
Range Resolution Accuracy Overload Protection
-50°C to 900°C 0.1°C ± 1% ± 1°C 30VAC or 60VDC

TRUE Power: (PF > 0.7 or θ < 45°)
Range Resolution Accuracy Overload Protection
60.00kW (<100A) 10W ± 5%rdg ± 20dgts
(50, 60Hz)
600VAC or 1000AAC
600.0kW (>100A) 100W 600VAC or 1000AAC

Apparent Power:
Range Resolution Accuracy Overload Protection
60.00kW (<100A) 10VA ± 2.5%rdg ± 20dgts
(50, 60Hz)
600VAC or 1000AAC
600.0kW (>100A) 100VA 600VAC or 1000AAC

Phase Angle: (50Hz, 60Hz)
Range Resolution Accuracy Sensitivity
-45° ~ 0° ~ +45° 0.1Hz ± 3.0% ACV>0.2V, ACA>6A

Frequency:
Range Resolution Accuracy Sensitivity
40Hz/1kHz 0.1Hz ± 0.5%rdg ± 2dgts ACV>0.2V, ACA>6A

General Specifications
Applicable standards IEC 1010-2-032, EN 61010-1, Pollution Degree 2
Jaw opening 40mm maximum
Display 3¾ digit LCD with 40 segment bar graph
Maximum reading 3999
Continuity ≤ 40Ω on 999.9Ω Range
Operating temperature 0°C to 50°C
Dimensions 228(L) x 76(W) x 39(H)mm, (9" x 3" x 1.5")
Weight 465g (batteries included), 1 lb
Accessories included User's Manual, 9V Battery, Test Leads, 1 pair of Alligator Clips, Carrying Case